Testing Transformer

Overview

The essential test transformer for preventive testing is a key test device used in power equipment inspection. With the development of China’s power industry, the voltage rating requirements for test transformers are also becoming higher. However, traditional oil-immersed test transformers, whether in terms of size, weight, or performance, are increasingly unable to meet the requirements for fieldwork.

Trusted by world-class brands & organizations of all sizes

Product Feature

With the advancement of basic scientific research in China and the application of new materials and technologies, sulfur hexafluoride gas (SF6) has been introduced into the field of power equipment. Due to the excellent insulating and arc-extinguishing properties of SF6, as well as its non-flammability, it has been widely applied as a new insulating medium.

After years of effort, our company has successfully developed the gas-insulated lightweight test transformer. Compared with traditional oil-immersed lightweight test transformers, this product is 20%–60% lighter (depending on voltage and capacity levels) and is free from oil contamination. The voltage rating of a single test transformer can reach up to 300 kV. With the use of new production processes, the technical performance of the product has significantly improved, making it especially suitable for fieldwork and frequent mobility.

Product Features:

  • The weight is reduced by 20%–60% (depending on voltage and capacity levels) and is free from oil contamination.
  • The voltage rating of a single test transformer can reach 300 kV.
  • The product’s technical performance has greatly improved, making it especially suitable for fieldwork and conditions that require frequent mobility.

Technical Parameters

Testing Transformer Technical Parameters

A testing transformer is a specialized electrical device used primarily for testing, calibrating, and verifying electrical systems, circuits, and components. It ensures the safe delivery of controlled, accurate voltage levels for system analysis, performance checks, and maintenance procedures. Testing transformers are widely used in laboratories, manufacturing plants, and electrical maintenance services to verify the operational integrity of equipment.

Capacity KVA Low Voltage Side High Voltage Side Temperature Variation 60-Minute Rise Dielectric Strength % No-load Current Dimensions (L×W×H) mm×mm×mm
Voltage V Current A Voltage KV Current mA kg
1.5/50 200 7.5 30 500 50 10 <4
3/50 200 15 50 500 50 10 <4
6/50 200 30 50 500 50 10 <4
10/50 200 50 100 500 50 10 <4
15/50 400 37.5 50 300 500 8 <4
20/50 400 50 50 400 500 8 <4
30/50 400 75 100 300 500 8 <4
50/50 400 125 100 500 500 8 <4
10/100 200 50 100 500 1000 8 <4
15/100 400 37.5 50 300 1000 8 <4
20/100 400 50 50 400 1000 8 <4
30/100 400 75 100 300 1000 8 <4
50/100 400 125 100 500 1000 8 <4
15/150 400 37.5 50 300 1500 8 <4
20/150 400 50 50 400 1500 8 <4
30/150 400 75 100 300 1500 8 <4
50/150 400 125 100 500 1500 8 <4
Let me know if you need further adjustments or explanations!

QC & Guarantee

Market Orientation and Service Commitment

In response to fierce market competition and to meet customer demands, our company adheres to a market-oriented approach and a customer-centric philosophy. We have earned widespread recognition from our clients through efficient, comprehensive services and superior product quality.

Our Commitments

  1. Product Lifespan Guarantee: The operational lifespan of our transformers is no less than 30 years.
  2. Strict Quality Control:
    • Upon receiving bid documents, we promptly initiate the evaluation process to ensure all customer requirements are fully addressed.
    • We carefully select certified suppliers and strictly follow quality management standards to control and inspect raw materials and components.
    • We produce high-quality, customer-satisfactory parts in full compliance with contract and technical agreement requirements.
  3. After-Sales Service Commitment:
    • All performance indicators and technical specifications of our transformers meet or exceed national standards.
    • Within 3 years of installation and commissioning, if any oil leakage occurs due to manufacturing defects in oil-immersed transformers, we will repair it at no cost.
    • For any critical component defects identified during production or issues discovered during installation, we prioritize resolution to meet project timelines, followed by thorough responsibility analysis and necessary repairs or replacements.
    • We welcome customers to supervise the manufacturing process at our facility and will provide full support.

After-Sales Support

We offer comprehensive after-sales services, including free guidance for installation and commissioning. After the product is operational, if the customer requires support, our service team will respond promptly:

  • Arrival on-site within 24 hours for locations within 300 km.
  • Arrival on-site within 48 hours for locations beyond 300 km.

Additionally, we have established a robust regular follow-up system. We conduct periodic written or on-site visits to monitor the performance of in-service products, ensuring our customers have continuous peace of mind.

International Service Methods

Remote Technical Assistance

Our service team provides 24/7 online technical support, including video calls, troubleshooting guides, and documentation, ensuring immediate assistance regardless of time zones.
Detailed remote diagnostics can be conducted using customer-provided data or live visual inspections.

On-Site Support

For complex issues, we dispatch experienced technicians to the customer site promptly, adhering to the agreed international response timelines.
On-site services include installation guidance, commissioning, maintenance, and repairs.

Dedicated Service Representatives

Each international client is assigned a dedicated service representative to coordinate all aspects of after-sales support, including issue resolution and regular follow-ups.

Local Service Partnerships

We collaborate with certified local service partners in key markets to ensure faster response times and efficient support. These partners are fully trained in our products and processes to uphold our quality standards.
Regular Follow-Up Visits

Post-installation, we perform scheduled follow-up visits, either in person or virtually, to monitor product performance and address customer feedback. This proactive approach ensures optimal operation and customer satisfaction.

Why This Matters

Our comprehensive international service system combines swift response, advanced technical support, and localized expertise to provide our global clients with reliable and professional after-sales services. We are committed to building lasting partnerships through consistent support and excellence.

FAQs

Testing Transformer FAQs

When purchasing an Testing Transformer, you may want to know the following questions & answers.

The Testing Transformer is specifically designed for testing electrical equipment such as switchgear, circuit breakers, transformers, and other high-voltage apparatus. These transformers typically operate within specific voltage ranges and power ratings, depending on the application for which they are intended (e.g., testing low-voltage or high-voltage equipment). Below are the general input and output voltage ranges and power ratings of Testing Transformers:

1. Input Voltage Range

The input voltage for a testing transformer is usually taken from a standard utility power supply or laboratory grid. The input voltage range is typically 50/60 Hz AC, depending on the region.

  • Standard Input Voltages:
    • Single-phase input: 110V to 240V (commonly 120V or 220V based on regional standards).
    • Three-phase input: 380V to 690V (typically 400V, 480V, or 600V based on the region).

These input voltages correspond to the power supply available in most regions, either single-phase or three-phase, and are typically adjusted to meet the requirements of specific testing purposes.


2. Output Voltage Range

The output voltage of a testing transformer is one of its most crucial parameters, as it determines the voltage levels to which equipment is subjected during testing. The output can be variable or fixed, depending on the design of the transformer.

  • Low-voltage testing transformers (for low-voltage or control systems):
    • Output range: 0-100V to 0-500V (depending on the type of testing and equipment under test).
  • High-voltage testing transformers (for testing high-voltage systems):
    • Output range: 0–10 kV to 0–100 kV or higher.
      • Common ranges include 1 kV, 5 kV, 15 kV, 25 kV, up to 100 kV or more.

Some advanced testing transformers are designed for very high voltages (up to 500 kV or more), which are used for specialized high-voltage insulation and dielectric testing.

Key Considerations for Output Voltage:

  • The output voltage can be either AC or DC, depending on the application. Most testing transformers are designed for AC output, but certain testing scenarios, such as testing insulation resistance or DC circuits, may require DC output transformers.
  • The output voltage is usually adjustable for testing purposes, allowing users to set the required test voltage depending on the specifications of the equipment being tested.

3. Output Power Rating

The power rating of the testing transformer is an important consideration when selecting a transformer for testing purposes. The power rating dictates how much load the transformer can supply while maintaining stable voltage output.

  • Typical Power Ratings:
    • Small Power Ratings (for testing low-voltage equipment, such as small transformers, control devices, or circuit breakers):
      • 0.5 kVA to 5 kVA (generally used for testing low-voltage equipment and components).
    • Medium Power Ratings (for testing larger electrical equipment or systems):
      • 5 kVA to 50 kVA (often used for testing medium-sized transformers, switchgear, or insulation systems).
    • Large Power Ratings (for high-voltage testing of large electrical equipment such as high-voltage circuit breakers, large transformers, or power systems):
      • 50 kVA to 500 kVA or more.

Power Rating Range by Application:

  • Low-Voltage Testing: Transformers with power ratings of 0.5 kVA to 10 kVA are typically used for low-voltage testing (e.g., testing electrical appliances, small transformers, or circuit breakers).
  • Medium-Voltage Testing: Power ratings of 10 kVA to 100 kVA are common for testing larger equipment, such as medium-voltage switchgear, motors, or medium-sized transformers.
  • High-Voltage Testing: For high-voltage tests, testing transformers with 100 kVA to 500 kVA or higher power ratings are used to perform insulation and dielectric strength tests on high-voltage equipment.

4. Summary of Typical Input, Output, and Power Ratings of Testing Transformers

ParameterLow Power Testing TransformerMedium Power Testing TransformerHigh Power Testing Transformer
Input Voltage110V–240V (single-phase) or 380V–690V (three-phase)380V–690V (three-phase)380V–690V (three-phase)
Output Voltage0–500V (adjustable)1 kV–25 kV (adjustable)10 kV–100 kV (adjustable or fixed)
Power Rating0.5 kVA–10 kVA10 kVA–50 kVA50 kVA–500 kVA or higher
Frequency50/60 Hz50/60 Hz50/60 Hz

5. Special Considerations for Testing Transformers

A. Voltage Regulation

  • Testing transformers often require good voltage regulation to ensure a stable voltage output under varying load conditions. This is particularly important in applications where precision voltage is critical for accurate testing.

B. Short Circuit and Overload Protection

  • Many testing transformers come equipped with overload protection features to prevent damage under short-circuit or overload conditions. These safety features are essential to avoid equipment failure during testing.

C. Cooling Requirements

  • For larger testing transformers, cooling systems (such as fans or oil cooling) may be necessary to maintain optimal operating temperatures during high-power testing.

D. Output Current

  • The output current of the transformer is typically defined by the power rating and output voltage. Testing transformers may have a current range typically up to 10–20 A for low- to medium-power transformers, and larger currents for higher power ratings.

E. Frequency Adjustments

  • In some cases, testing transformers can offer frequency adjustment for testing under different frequency conditions (e.g., 50 Hz, 60 Hz, or even 400 Hz for avionics applications).

Conclusion

The input and output voltage ranges and power ratings of testing transformers vary based on the application and size of the equipment being tested. Typical voltage output ranges from 0–500V for low-voltage testing to 1 kV–100 kV for high-voltage equipment testing. Power ratings range from 0.5 kVA for small applications to 500 kVA or more for large-scale high-voltage tests. Be sure to select a transformer that meets the voltage and power requirements for the specific testing application.

The frequency response range of a Testing Transformer and its suitability for AC and DC testing depend on its design and intended application. Generally, testing transformers are designed to primarily handle AC voltage testing, but their frequency response characteristics and capability for DC testing can vary depending on the transformer type and model. Here’s a detailed breakdown:


1. Frequency Response Range of Testing Transformers

The frequency response of a testing transformer refers to its ability to operate effectively over a range of input frequencies. Most testing transformers are designed to operate at the standard 50 Hz or 60 Hz AC mains frequency, but specialized designs are available for specific applications.

AC Frequency Response:

  • Standard Testing Transformers (AC):
    • The majority of testing transformers are designed to operate at 50 Hz or 60 Hz (depending on the region and standard AC power supply). This is suitable for most industrial and electrical equipment testing.
    • Frequency response range: Typically, these transformers can handle input frequencies within the 50–60 Hz range, with some limited tolerance to slight variations in frequency, such as 47–63 Hz.
    • Some transformers are built to accommodate wide-range frequencies (e.g., 45–400 Hz) for specialized applications like aerospace, telecommunications, or military testing.

High-Frequency Testing:

  • High-frequency transformers (for testing at frequencies higher than 60 Hz) are used in niche applications, especially in high-voltage testing where equipment may need to be tested under conditions resembling transient or high-frequency pulses.

    • High-frequency testing transformers may offer response ranges extending up to 400 Hz or more, and can be used for impulse testing (e.g., surge testing, insulation testing).
  • Wide-frequency range transformers are used in inductive heating or power supplies for RF circuits, where the frequency range may extend from 50 Hz up to 100 kHz or higher.


2. DC Testing Capability

While most Testing Transformers are designed for AC voltage testing, there are certain designs available that can provide DC voltage output for testing DC systems or insulation resistance testing.

AC vs. DC Output:

  • AC Testing Transformers: These are primarily designed to produce sinusoidal AC voltage for AC equipment testing, such as power transformers, switchgear, circuit breakers, and other electrical apparatus.

  • DC Testing Transformers: These are less common and are typically designed for DC insulation testing or high-voltage DC dielectric strength testing of cables, motors, and other DC systems. They typically involve the use of a rectifier or DC converter circuit to convert AC input to DC output.

    • For example, some high-voltage testing equipment or electrical safety testers may require DC testing to assess insulation integrity under DC voltage conditions. In such cases, a transformer with an integrated rectifier can convert the AC input into DC output.

Suitability for DC Testing:

  • Rectified Output: Many high-voltage AC testing transformers can be used for DC testing by incorporating rectifiers to provide DC voltage for insulation tests.
  • Dedicated DC Testing: For pure DC testing (especially for equipment like DC motors, batteries, or insulation materials), Dedicated DC High Voltage Testing Equipment would be required, which may include separate DC power supplies designed specifically for this purpose.

3. Applications and Limitations

AC Applications:

  • Most Testing Transformers are used for AC voltage testing. Their primary function is to provide a stable AC voltage at specified test levels, which is required for a variety of dielectric tests, insulation tests, and voltage withstand tests.

  • These transformers are widely used for testing power system components, such as:

    • Circuit breakers (for AC withstand voltage testing)
    • Insulating materials (for AC dielectric strength testing)
    • Power transformers (for AC voltage tests)
    • Electrical equipment (for routine maintenance testing)

DC Applications:

  • DC testing requires specialized equipment. Some testing transformers are designed with a built-in rectifier or are used in conjunction with separate rectifier units to convert AC into DC for testing DC insulation or high-voltage DC resistance testing.

  • DC testing transformers are typically used in:

    • DC insulation resistance testing of electrical systems (e.g., cables, DC motors, or batteries).
    • High-voltage DC dielectric testing (testing the insulation capabilities of DC equipment under high voltage).
  • Limitations: Testing transformers designed for AC are not suitable for pure DC applications without an additional rectification stage. Additionally, DC testing may require specialized surge generators or impulse testers in cases of high-voltage DC testing.


4. Summary of Frequency Response and Suitability for AC and DC Testing

AspectTesting Transformer
Frequency ResponseTypically 50 Hz or 60 Hz AC, some can handle 45–400 Hz or higher for specialized testing
Suitability for AC TestingHighly suitable for most AC voltage testing applications, including power systems and equipment
Suitability for DC TestingLimited—AC transformers can be used for DC testing with a rectifier or a separate DC testing unit; pure DC testing requires specialized equipment
High-frequency ApplicationsAvailable in specialized models for applications requiring high-frequency AC testing (e.g., up to 100 kHz for RF testing)

Conclusion

  • The frequency response of most testing transformers is optimized for 50 Hz or 60 Hz AC applications, which are the most common frequencies for electrical power systems.
  • Some testing transformers can handle higher frequencies (up to 400 Hz or more) for specialized tests, such as high-frequency surge or dielectric testing.
  • For DC testing, specialized DC high-voltage testers or AC transformers with rectifiers are required. Standard AC testing transformers are typically not suitable for pure DC testing without additional components, such as rectifiers or DC power supplies.

Yes, Testing Transformers are generally designed to comply with relevant international standards to ensure safety, performance, and reliability during testing applications. These standards are crucial for both the manufacturing and operation of testing transformers, especially when used in the testing of electrical equipment like transformers, circuit breakers, and switchgear.

Relevant Standards for Testing Transformers

Here are the key standards that typically apply to testing transformers for electrical testing equipment:


1. IEC Standards (International Electrotechnical Commission)

The IEC standards provide comprehensive guidelines and requirements for the design, safety, and performance of electrical equipment, including testing transformers.

  • IEC 60076Power Transformers
    This standard applies to power transformers, including those used for testing purposes. It outlines performance criteria, such as voltage ratings, losses, and mechanical strength, which are crucial for testing transformers used in power system applications.

  • IEC 60289Shunt Reactors
    For testing transformers used in reactive power or inductive testing, this standard covers design and test requirements for shunt reactors, including transformers designed to simulate inductive load characteristics.

  • IEC 60529Degrees of Protection Provided by Enclosures (IP Code)
    This standard specifies the level of protection testing transformers must have against dust, moisture, and accidental contact. The IP rating is critical when the transformer is used in challenging environments, such as outdoor substations or industrial settings.

  • IEC 61010-1Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use
    Testing transformers used in laboratories or for equipment calibration should comply with this standard to ensure safe operation during testing. It includes requirements for electrical safety, protection against electric shock, and operational limits.

  • IEC 61378-1Converter Transformers
    For testing transformers used in high-voltage DC applications, this standard outlines performance criteria such as insulation systems, cooling methods, and mechanical properties, which could be applicable if the transformer is intended for such specialized testing.

  • IEC 60076-3Insulation Levels
    This standard ensures that testing transformers designed for high-voltage testing meet the necessary insulation strength requirements. It’s essential for transformers that generate high voltages for insulation testing.


2. UL Standards (Underwriters Laboratories)

In regions like North America, UL standards play a key role in ensuring the safety and reliability of electrical devices, including testing transformers.

  • UL 60601-1Medical Electrical Equipment
    Although this standard is primarily for medical equipment, if testing transformers are used in a medical setting for device testing, they must comply with UL 60601-1. This standard addresses electrical safety and leakage currents in electrically operated medical devices.

  • UL 5085-1Low Voltage Transformers
    Testing transformers designed for low-voltage AC applications often fall under UL 5085-1, which covers the construction, performance, and safety of low-voltage transformers used in various applications, including testing equipment.

  • UL 1446Class Insulation Systems
    This standard ensures that insulation systems within transformers meet fire safety and operational limits, which is crucial when testing high-voltage electrical equipment. It also defines the temperature ratings and cooling requirements for transformers used in high-energy tests.

  • UL 498Attachment Plugs and Receptacles
    While typically used for plug devices, this standard is relevant if a testing transformer is fitted with connectors that could potentially be used for interfacing with various test devices, ensuring safe electrical connections during testing.


3. ASTM Standards (American Society for Testing and Materials)

ASTM provides a range of testing standards related to electrical equipment and transformers that would be applicable to testing transformers, particularly those used for high-voltage or special-purpose testing.

  • ASTM D877Dielectric Breakdown Voltage of Insulating Liquids
    This standard is relevant for testing transformers used in oil-filled applications (e.g., power transformers or oil-cooled transformers). It specifies how to measure the dielectric strength of insulating oils, which is essential when using testing transformers to assess the insulation strength of equipment.

  • ASTM D1816Dielectric Breakdown Voltage of Electrical Insulating Oils
    For testing transformers that use oil as an insulating medium, this standard provides methods for testing the dielectric breakdown of insulating oils, ensuring safe and reliable operation under high-voltage testing conditions.

  • ASTM F855Dielectric Testing of Electrical Insulation Materials
    For transformers used in dielectric testing of materials, this standard defines procedures for testing the dielectric breakdown voltage and is important for testing transformers used in high-voltage insulation resistance testing.

  • ASTM F1030Test Method for Dielectric Properties of Solid Insulating Materials
    If the testing transformer is used to test the dielectric properties of solid insulating materials, such as those found in cables or circuit breakers, this standard outlines the methods for applying high-voltage testing to determine the dielectric strength.


4. Additional Standards to Consider

  • ISO 9001Quality Management Systems
    This global standard is crucial for manufacturers of testing transformers to demonstrate their commitment to maintaining high standards of quality control during production. While not specific to testing transformers, this certification ensures that the manufacturing process of the transformer is robust and consistently produces reliable products.

  • IEC 61869-1Instrument Transformers
    For specialized instrument transformers used for calibration and high-accuracy measurements in testing equipment, this standard defines performance, accuracy, and insulation requirements for transformers that are used in test setups for high-precision measurements.

  • IEEE C57.12.00Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    This standard is applicable to liquid-immersed transformers, and if the testing transformer is of this type (oil-filled, for example), it outlines the general requirements for design, materials, and performance.


Conclusion: Compliance with Standards

Most Testing Transformers are designed to comply with the following standards:

  • IEC standards, such as IEC 60076 for power transformers and IEC 61010 for safety, provide the framework for international compliance.
  • UL standards, especially UL 5085 and UL 1446, ensure that transformers are safe for use in North America.
  • ASTM standards like D877 and D1816 are applicable for transformers used in high-voltage and dielectric testing.

For specific applications, the testing transformer must comply with the relevant standards for the electrical testing, voltage ratings, insulation systems, and safety requirements.

If you are dealing with a specific transformer model or application, it’s important to verify its certification with the manufacturer to ensure full compliance with these standards.

A Testing Transformer is a versatile piece of equipment used in various electrical and power systems testing applications. Depending on its design and capabilities, a testing transformer can support a wide range of tests. Below are the types of tests that a Testing Transformer can typically support, such as insulation resistance testing, high voltage testing, power quality analysis, and more:


1. Insulation Resistance Testing

Purpose: To measure the resistance of electrical insulation and verify its integrity under high-voltage stress.

  • Test Details: This test involves applying a high voltage to the electrical insulation (such as cables, transformers, or motors) and measuring the resistance or leakage current to determine the quality of the insulation.

  • Testing Transformer Role:

    • High-voltage output: The testing transformer provides the necessary high-voltage output (typically in the range of 1 kV to 100 kV) to stress the insulation.
    • DC voltage output (in some models): Certain testing transformers are equipped with a rectifier to convert AC to DC for DC insulation resistance testing.
  • Test Equipment Supported: Insulation resistance testers or megohmmeters often use testing transformers to generate the high voltage required for testing the insulation resistance of equipment.


2. High-Voltage Testing

Purpose: To test the dielectric strength of electrical insulation by subjecting it to high voltage beyond normal operating conditions.

  • Test Details: High-voltage testing is used to ensure that electrical equipment like transformers, switchgear, and cables can withstand the rated operating voltage and occasional surges without breakdown.

  • Testing Transformer Role:

    • High-voltage generation: The testing transformer provides the required AC high voltage to the test object (equipment under test), which can range from 1 kV to 100 kV or higher, depending on the application.
    • Voltage application: The transformer applies the voltage for a specified duration to simulate operating conditions and verify the dielectric strength of the equipment.
    • Partial discharge testing: In some cases, high-voltage testing transformers are used for partial discharge (PD) testing of insulation in cables and other high-voltage systems.

3. Dielectric Strength Testing

Purpose: To assess the ability of insulating materials or electrical components to withstand electrical stress without failing.

  • Test Details: This test involves applying a high-voltage stress to a sample of insulation or an entire electrical component to ensure that it does not fail under extreme conditions.

  • Testing Transformer Role:

    • The transformer provides AC or DC high-voltage output to test the dielectric strength of insulation materials like cables, transformers, capacitors, etc.
    • Test objects: Common objects tested include cables, bushings, electrical panels, transformers, and circuit breakers.
  • Voltage Levels: The voltage applied typically exceeds the normal operating voltage of the equipment to verify that the insulation can withstand potential electrical surges or faults.


4. Power Frequency Withstand Testing

Purpose: To simulate the normal operating conditions of electrical equipment and determine whether it can withstand continuous operation under rated voltage and frequency.

  • Test Details: Power-frequency withstand tests are conducted by applying AC voltage at the rated frequency (50 Hz or 60 Hz) and voltage levels to electrical components to simulate normal operating conditions.

  • Testing Transformer Role:

    • The testing transformer provides a steady AC output at the specified voltage and frequency for extended periods (often for several minutes to hours) to ensure the tested equipment can safely operate under these conditions.
    • It helps to simulate continuous load conditions without stressing the insulation or component prematurely.

5. Lightning Impulse and Switching Impulse Testing

Purpose: To simulate the effects of lightning strikes or switching operations in the electrical system and test equipment resilience.

  • Test Details: These tests apply high-voltage impulse waves to electrical systems to simulate the effects of lightning strikes (lightning impulse) or switching events in power systems (switching impulse).

  • Testing Transformer Role:

    • Impulse transformers or high-voltage testing transformers with impulse generation capabilities are used to simulate these lightning and switching surge conditions.
    • The transformer generates impulse voltages that simulate high-energy events, testing the insulation strength of equipment like transformers, circuit breakers, and cables against transient overvoltages.

6. Power Quality Analysis and Harmonics Testing

Purpose: To evaluate the quality of power delivered by a system and measure any disturbances or harmonics that may affect equipment performance.

  • Test Details: This test involves analyzing the voltage waveform for any irregularities, such as harmonics, voltage dips, spikes, and other anomalies that can affect equipment performance.

  • Testing Transformer Role:

    • While testing transformers themselves are not typically used for power quality analysis, they play a role in generating the test voltages required for evaluating how electrical equipment responds to these disturbances.
    • Power analyzers or harmonics analyzers can be used alongside testing transformers to monitor voltage waveforms under different testing conditions (e.g., high-voltage surge, harmonic distortion).
    • Transformers can help simulate distorted voltage waveforms to test how sensitive equipment like motors, drives, and electronic devices is to voltage variations and harmonic content.

7. Impulse Insulation Testing (Surge Testing)

Purpose: To simulate and test the equipment’s response to electrical surges (such as from switching or lightning) that might cause insulation breakdown or failure.

  • Test Details: Surge or impulse testing applies high-voltage pulses to equipment to simulate real-world scenarios like switching transients or lightning strikes.

  • Testing Transformer Role:

    • Specialized impulse testing transformers are used to generate high-energy surge pulses to assess insulation strength under these transient conditions.
    • Surge generators may also be connected with the testing transformer to apply high-voltage surges to test high-voltage equipment.

8. Short Circuit Testing

Purpose: To test electrical equipment for its ability to withstand short-circuit conditions, including protection mechanisms like circuit breakers and fuses.

  • Test Details: This test applies high currents to simulate a short-circuit scenario and test the thermal withstand and mechanical stresses that electrical equipment can endure.

  • Testing Transformer Role:

    • Short-circuit testing transformers can provide the necessary high current under short-circuit conditions, allowing for testing of protective devices like circuit breakers, fuses, and protective relays to ensure they react correctly.
    • Testing transformers can be used to deliver high current for the short-circuit test while monitoring for tripping times and equipment performance.

9. Low Voltage Testing (Functionality & Calibration Tests)

Purpose: To verify the proper functioning and calibration of electrical equipment at low voltage levels.

  • Test Details: This is typically done for low-voltage systems (e.g., 120V, 240V) to ensure devices like circuit breakers, meters, and transformers operate within the specified voltage tolerances and perform correctly.

  • Testing Transformer Role:

    • Low-voltage testing transformers can provide steady and controlled low voltage to test electrical equipment under normal operating conditions.

Conclusion

A Testing Transformer can support a variety of tests depending on its design and the capabilities of the test setup. Key tests include:

  • Insulation resistance testing (for determining insulation integrity).
  • High-voltage dielectric testing (to verify equipment can withstand extreme voltage conditions).
  • Lightning and switching impulse testing (for simulating surge events).
  • Power quality analysis (to detect harmonic distortions and voltage irregularities).
  • Surge and impulse testing (to assess response to electrical transients).
  • Short-circuit testing (to evaluate the behavior under fault conditions).
  • Low voltage testing (for functionality and calibration checks).

The testing transformer provides high-voltage outputs, which are essential for these tests, either directly or through additional equipment like surge generators, megohmmeters, and voltage analyzers.

The Testing Transformer is an essential component in various electrical testing applications, particularly for high-voltage testing, insulation resistance testing, and dielectric strength testing. To ensure safe operation, prevent damage, and protect both the transformer and the equipment being tested, a range of protection features are typically integrated into these transformers. Below are the key protection features commonly found in Testing Transformers:


1. Overvoltage Protection

Purpose: To protect the transformer and connected equipment from damage due to excessive voltage.

  • Overvoltage Protection Mechanism:
    • Automatic Voltage Regulation: Some testing transformers have built-in voltage regulators that ensure the output voltage remains within the set range, even if there are fluctuations in the input power supply.
    • Overvoltage Relays/Alarms: These are set to trigger when the output voltage exceeds predefined levels, disconnecting the load or triggering an alarm to alert the operator. The transformer may automatically shut down to prevent damage to itself or the connected test equipment.
    • Crowbar Circuit: In high-voltage testing transformers, a crowbar circuit may be used to quickly short-circuit the output in the event of an overvoltage condition, rapidly discharging excess energy and protecting the system.

2. Overload Protection

Purpose: To prevent damage to the transformer from excessive current flow, which can lead to overheating or insulation failure.

  • Overload Protection Mechanism:
    • Current Limiting: Testing transformers often have built-in current-limiting features to prevent excessive current draw, especially when the load is lower resistance than expected (for example, a fault condition in the device under test).
    • Overload Relays: These relays sense when the current exceeds safe operating levels. Upon detection, they can trip a circuit breaker or activate an alarm, shutting off the transformer or disconnecting the load.
    • Thermal Overload Protection: Some testing transformers are equipped with thermal sensors (e.g., thermistors) that monitor the internal temperature of the transformer. If the temperature exceeds safe limits due to overload, a protective relay will disconnect the transformer from the load to prevent overheating.

3. Short Circuit Protection

Purpose: To protect the transformer from damage caused by short-circuit conditions, which can result in excessive current flow and potential transformer failure.

  • Short Circuit Protection Mechanism:
    • Automatic Disconnection: When a short circuit is detected in the load (such as in the device being tested), the transformer may be automatically disconnected by fuse protection or circuit breakers. These devices interrupt the circuit to prevent damage to the transformer and other equipment.
    • Current Sensing Circuits: Transformers often include current transformers (CTs) or overcurrent protection relays that sense unusually high current that typically indicates a short circuit. If such conditions occur, the protection system will immediately activate to disconnect the output.
    • Inrush Current Limiting: Some testing transformers also incorporate features to limit the inrush current when a transformer is first energized or when a short is detected during the startup of the equipment.

4. Temperature Monitoring and Protection

Purpose: To protect the transformer from overheating, which could damage its windings or insulation.

  • Temperature Protection Mechanism:
    • Thermal Sensors: Many testing transformers are equipped with thermistors or RTDs (Resistance Temperature Detectors) to continuously monitor the transformer’s temperature during operation. If the temperature exceeds the rated limit (often due to overload or environmental conditions), the transformer will either automatically disconnect the load or sound an alarm to warn the operator.
    • Overtemperature Relays: These relays can trigger shutdown mechanisms (such as disconnecting the primary or secondary windings) if the transformer reaches dangerous temperature levels, thereby preventing thermal damage or fire hazards.
    • Cooling Fans or Heat Exchangers: In larger testing transformers, especially those that operate at high power levels, the transformer may be equipped with active cooling systems such as fans, heat exchangers, or oil coolers. These systems are monitored for operational status, and if they fail, an alarm or shutdown system will be triggered to protect the transformer from overheating.

5. Ground Fault Protection

Purpose: To prevent electrical shock hazards or potential damage caused by unintended current paths to ground.

  • Ground Fault Detection:
    • Ground Fault Circuit Interrupter (GFCI): Some testing transformers are equipped with GFCI to detect leakage current to ground and automatically disconnect the transformer if a fault occurs. This ensures operator safety and protects the transformer from potential damage.
    • Earth Leakage Protection: A similar system may monitor for earth leakage current and will trip if any significant current is detected flowing through the ground, signaling a fault in the system.

6. Arc Flash Protection

Purpose: To safeguard operators and equipment from the potentially deadly effects of arc flashes, which occur when an electrical fault causes a high-energy discharge.

  • Arc Flash Detection and Mitigation:
    • Arc Flash Relays: Some modern testing transformers are equipped with arc flash protection systems that can sense the presence of an arc and disconnect the transformer from the circuit very quickly. This minimizes the impact of the arc flash and protects both the transformer and personnel working around the equipment.

7. Surge Protection

Purpose: To protect the transformer from high-energy surges or transients, which can occur from lightning strikes, power line crosses, or switching events.

  • Surge Protection Mechanism:
    • Surge Arresters: Surge arresters or surge protection devices (SPDs) are often integrated into the transformer design to clamp high-voltage surges, limiting the voltage to safe levels and preventing insulation breakdown.
    • Overvoltage Crowbar Circuits: In addition to surge arresters, crowbar circuits (as mentioned above) can also act to short-circuit high voltage surges, discharging them safely to ground.

8. Manual and Automatic Reset Features

Purpose: To protect against prolonged faults and ensure that the transformer can return to operation once the fault is cleared.

  • Reset Mechanism:
    • After protective mechanisms (overload, short-circuit, overvoltage, etc.) are triggered, the testing transformer may have an automatic reset feature that allows it to resume operation once the fault condition has been cleared or the safety limits have returned to normal levels.
    • Manual reset: For some protection features, especially in the case of persistent faults, the operator may need to reset the system manually to resume testing.

9. Protection from Overfrequency and Underfrequency

Purpose: To protect the transformer in case of deviations in input supply frequency, which can affect transformer performance and safety.

  • Frequency Protection:
    • Some testing transformers include built-in frequency protection to detect overfrequency or underfrequency conditions in the input supply and either adjust the output or disconnect the transformer to prevent damage.

10. Fault Monitoring and Alarming Systems

Purpose: To provide real-time feedback on the condition of the transformer and alert operators to any faults or abnormalities.

  • Real-Time Monitoring: Many modern testing transformers are equipped with digital control panels or monitoring systems that provide detailed feedback on the operation status of the transformer, including voltage, current, temperature, and fault conditions.
  • Alarms and Indicators: Visual and audible alarms are used to alert operators when protection mechanisms are triggered (e.g., flashing lights, sirens) to ensure prompt corrective action is taken.

Conclusion

The Testing Transformer typically integrates a wide range of protection features to safeguard both the equipment and the operators:

  1. Overvoltage Protection: Automatic voltage regulation, overvoltage relays.
  2. Overload Protection: Current limiting, overload relays, and thermal protection.
  3. Short Circuit Protection: Automatic disconnection, current sensing circuits, inrush current limiting.
  4. Temperature Monitoring: Thermal sensors, overtemperature relays, and active cooling.
  5. Ground Fault Protection: Ground fault circuit interrupters and earth leakage protection.
  6. Arc Flash Protection: Arc flash relays for rapid disconnection.
  7. Surge Protection: Surge arresters, crowbar circuits.
  8. Manual/Automatic Reset: Reset features after fault conditions.
  9. Over/Underfrequency Protection: Frequency monitoring and protection.
  10. Fault Monitoring: Alarms and real-time fault detection for safety and operational efficiency.

These protection features ensure safe and reliable operation of the testing transformer, preventing damage to both the transformer and the equipment being tested, while ensuring operator safety.

Ultimate Guide

Testing Transformer Ultimate Guide

Faster global delivery

lifespan > 30 years

Top10 Power equipment cop in CN
National-level technology center

Why Choose us ?

Built to last,
engineered to perform.

Taishan Transformer is a key national-level manufacturer specializing in transformers, recognized as a “Contract-Honoring and Promise-Keeping” enterprise, a high-tech enterprise, and a national-level enterprise technology center. It is recommended in the national directory for rural and urban power grid construction and renovation, as well as a recommended supplier of major electromechanical equipment for hydropower projects. Its products have been awarded the title of “National Quality Inspection Qualified Product – Quality Trustworthy Product” and “Nationally Recognized Product for Mechanical Industry Users.

Our Project

Our products not only dominate the domestic market but are also exported to more than 30 countries and regions, including Russia, Southeast Asia, Africa, and the Americas, serving industries such as power, municipal engineering, metallurgy, and petrochemicals.

Bangladesh
CRRC Corporation Limited
oil-immersed transformers
Australia
FSGT(HK) Limited
oil-immersed transformers
Vietnam
CMT Southern Metropolis
oil-immersed transformers
Zambia
ITEZHI TEZHI POWER
oil-immersed transformers
Poland
Electro- Alfa International SRL
oil-immersed transformers
russia
Irkutsk Power Grid Corp
oil-immersed transformers
Zimbabwe
Zimbabwe power company
oil-immersed transformers
Bolivia
SinoHydro Corporation
oil-immersed transformers

Get a Quote / Support for Your Project

  • Don’t worry, we hate spam too!